The PBR panel’s deep ribs create an even-shadowed appearance. The area between the major ribs is reinforced with minor ribs. PBR is one of the most economical panel systems and can be used for both roof and wall applications.

Gauge
  • 26 gauge (standard)
  • 24 gauge
  • 22 gauge

 

Length
  • 45′ maximum length is standard but longer lengths are available by special request

 

Dimensions
  • 36″ by 1 1/4″

 

Finish
  • Galvalume Plus®
  • Signature® 200
  • Signature® 300
Limitations
  • Not designed for coverage over bar joist or to be used as rigid secondary; Five foot on center purlin spacing

 

Fasteners
  • Standard coated, zinc- aluminum cast head, or stainless steel head screw

 

Usage
  • Roof, wall, liner, mansard, and soffit panel applications

Attributes

  1. Reverse rolled profile
  2. Purlin bearing leg
  3. Installation may start at either end
  4. Economical profile
  5. 36″ coverage
  6. Wind uplift rating
  7. Diaphragm action
  8. Light transmitting panels
  9. Finish warranty

Advantages

  1. The panel can serve as an alternate wall panel by putting the paint finish on the under side
  2. An additional leg is rolled on one side of lap rib to facilitate installation
  3. Flexible installation
  4. Cost effective
  5. Ease of installation
  6. The panel qualifies for UL® 90 in multiple construction numbers
  7. The panel configuration enhances diaphragm capabilities for purlin stability
  8. Profile light transmitting panels are available for the PBR panel
  9. Used with long-life fasteners this panel has a 25-year warranty

PBR Roof – Section Properties

  NEGATIVE BENDING POSITIVE BENDING
PANEL GAUGE Fy KSI WEIGHT PSF Ixe IN.4/FT. Sxe IN.3/FT. Maxo KIP-IN. Ixe IN.4/FT. Sxe IN.3/FT. Maxo KIP-IN.
29 60* 0.75 0.0219 0.0357 1.2835 0.0242 0.0234 0.8423
26 60* 0.94 0.0302 0.0511 1.8366 0.0369 0.0372 1.3373
24 50 1.14 0.0404 0.0733 2.1953 0.0506 0.0521 1.5594

*Fy is 80-ksi reduced to 60-ksi in accordance with the 2001 Edition of the North American Specification For Design Of Cold-Formed Steel Structural Members – A2.3.2.

Properties Notes:
  1. All calculations for the properties of PBR panels are calculated in accordance with the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members.
  2. Ixe is for deflection determination.
  3. Sxe is for bending.
  4. Maxo is allowable bending moment.
  5. All values are for one foot of panel width.

Allowable Uniform Loads In Pounds Per Square Foot

drawing_pbr

Support Spacing

29 Gauge thickness (0.0133″), Fy = 60 ksi, Fu = 61.5 ksi
SPAN TYPE LOAD TYPE Support Spacing
3.0 4.0 5.0 6.0 7.0 8.0 9.0
1-SPAN Wind Suction 93.96 52.85 33.83 23.49 17.26 13.21 10.44
Gravity/Press 67.01 32.53 16.66 9.64 6.07 4.07 2.86
2-SPAN Wind Suction 61.91 37.19 24.61 17.42 12.95 10.00 7.94
Gravity/Press 70.40 45.25 30.46 21.79 16.31 12.65 9.40
3-SPAN Wind Suction 73.00 44.74 29.96 21.36 15.96 12.36 9.84
Gravity/Press 80.00 53.51 36.58 22.72 14.31 9.59 6.73
4-SPAN Wind Suction 69.50 42.31 28.22 20.07 14.97 11.58 9.21
Gravity/Press 77.00 50.89 34.62 24.72 15.57 10.43 7.32
26 Gauge thickness (0.0181″), Fy = 60 ksi, Fu = 61.5 ksi
SPAN TYPE LOAD TYPE Support Spacing
3.0 4.0 5.0 6.0 7.0 8.0 9.0
1-SPAN Wind Suction 133.90 75.32 48.21 33.48 24.59 18.83 14.88
Gravity/Press 119.08 52.22 26.74 15.47 9.74 6.53 4.58
2-SPAN Wind Suction 114.40 66.58 43.32 30.37 22.44 17.24 13.66
Gravity/Press 105.60 71.30 46.51 32.64 24.14 18.56 13.88
3-SPAN Wind Suction 138.48 81.61 53.45 37.61 27.85 21.44 17.00
Gravity/Press 120.00 87.15 57.27 34.84 21.94 14.70 10.32
4-SPAN Wind Suction 130.69 76.69 50.12 35.22 26.06 20.05 15.89
Gravity/Press 115.50 81.97 53.73 37.73 23.76 15.92 11.18
24 Gauge thickness (0.0223″), Fy = 50 ksi, Fu = 60 ksi
SPAN TYPE LOAD TYPE
3.0 4.0 5.0 6.0 7.0 8.0 9.0
1-SPAN Wind Suction 126.84 71.35 45.66 31.71 23.30 17.84 14.09
Gravity/Press 125.69 70.70 38.51 22.28 14.03 9.40 6.60
2-SPAN Wind Suction 120.59 69.04 44.56 31.09 22.91 17.57 13.90
Gravity/Press 117.33 69.65 44.96 31.37 23.11 17.73 14.03
3-SPAN Wind Suction 148.17 85.44 55.34 38.68 28.53 21.90 17.34
Gravity/Press 133.33 86.17 55.82 39.02 28.79 19.34 13.58
4-SPAN Wind Suction 139.13 80.03 51.77 36.16 26.66 20.46 16.19
Gravity/Press 128.33 80.71 52.22 36.48 26.90 20.57 14.45
22 Gauge thickness (0.0286″), Fy = 50 ksi, Fu = 60 ksi
SPAN TYPE LOAD TYPE Support Spacing
3.0 4.0 5.0 6.0 7.0 8.0 9.0
1-SPAN Wind Suction 164.57 92.57 59.25 41.14 30.23 23.14 18.29
Gravity/Press 174.46 98.14 52.70 30.50 19.21 12.87 9.04
2-SPAN Wind Suction 168.30 96.14 61.98 43.21 31.83 24.41 19.31
Gravity/Press 159.37 90.89 58.55 40.81 30.04 23.04 18.22
3-SPAN Wind Suction 207.24 119.12 77.03 53.80 39.67 30.44 24.09
Gravity/Press 196.54 112.72 72.82 50.83 37.23 24.94 17.52
4-SPAN Wind Suction 194.44 111.53 72.04 50.29 37.06 28.43 22.50
Gravity/Press 184.31 105.50 68.08 47.50 34.99 26.54 18.64

Note: For 12″ panel information please contact Robertson.

Allowable Uniform Loads Notes:
  1. Allowable loads are based on uniform span lengths and Fy = 50 ksi.
  2. LIVE LOAD is limited by bending, shear, combined shear and bending and web crippling.
  3. Allowable loads consider a maximum deflection ratio of L/180.
  4. The weight of the panel has not been deducted from the allowable loads.
  5. THE ALLOWABLE UNIFORM LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.
  6. Please contact manufacturer or manufacturer’s website for most current allowable wind uplift loads.
  7. The use of any field seaming machine other than that provided by the manufacturer may damage the panels, void all warranties and will void all engineering data.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

EFFECTIVE NOVEMBER 3, 2004 SUBJECT TO CHANGE WITHOUT NOTICE